wires to solder lugs and determine the orientation A, B, or
C, snap the connector back together, pull excess wires
out of strain relief, and tighten strain nut. Plug into electric
housing and secure with screw.
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
ELECTRICAL INSTALLATION
The module can only switch loads that consume between
2.5 and 90 watts, or have 5000 to 150 impedence
respectively. If the load draws less than 2.5 watts, a 0.47
uF loading capacitor is required. This capacitor will
increase the power consumption and ensure complete
conduction. See Figure 3. Wiring according to Figure 3
will provide conduction over 15-20% of full scale, above
or below the flow rate set point. For loads greater than 90
watts, see Figures 4 and 5.
CAUTIONS
WARNING: Due to incompatibility,
Polysulfone flow meters SHOULD
NOT be used for monitoring the
following fluids: ACETONE, ALCOHOL,
BENZENE, CARBON DISULFIDE, FREON 11,
KEROSENE, LIQUID PROPANE, NAPHTHA,
AND PERCHLOROETHYLENE.
Other chemicals may also be incompatible with
Polysulfone. When in doubt, the meter should be tested in
a non-critical application under low pressure conditions to
determine compatibility. Also note that some chemicals
become more aggressive when heated. An acceptable
application may become unsafe at elevated temperatures.
CAUTION: These flowmeters are unidirec-
tional devices. The piston acts as a check
valve to block flow in the reverse direction,
causing an excessive pressure differential
which could result in damage to internal
components.
!
!